Author(s):
Y. Hamada, A. Fujisawa, H. Iguchi, A. Nishizawa and Y. Kawasumi
-
Title:
A Tandem Parallel Plate Analyzer
Date of publication:
Nov. 1996
-
Key words:
analyzer, parallel plate analyzer, beam, HIBP
-
Abstract:
By a new modification of a parallel plate analyzer the second order focus is obtained in an arbitrary injection angle. This kind of an analyzer with a small injection angle will have an advantage of small operational voltage, compared to the Proca and Green analyzer where the injection angle is 30 degrees. Thus, the newly proposed analyzer will be very useful for the precise energy measurement of high energy particles in MeV range.
-
|