NIFS-761

FULL TEXT (PDF, 1532 KB)


Author(s):

K. Yamazaki, S. Imagawa, T. Muroga, A. Sagara, S. Okamura

Title:

System Assessment of Helical Reactors in Comparison with Tokamaks

Date of publication:

Oct. 2002

Key words:

IAEA, fusion energy conference, Lyon

Abstract:

A comparative assessment of tokamak and helical reactors has been performed using equivalent physics/engineering model and common costing model. Higher-temperature plasma operation is required in tokamak reactors to increase bootstrap current fraction and to reduce current-drive (CD) power. In helical systems, lower-temperature operation is feasible and desirable to reduce helical ripple transport. The capital cost of helical reactor is rather high, however, the cost of electricity (COE) is almost same as that of tokamak reactor because of smaller re-circulation power (no CD power) and less-frequent blanket replacement (lower neutron wall loading). The standard LHD-type helical reactor with 5% beta value is economically equivalent to the standard tokamak with 3% beta. The COE of lower-aspect ratio helical reactor is on the same level of high-beta_N tokamak reactors.